RIGEL 2 MT-A420

PV module temperature sensor, analog 4-20 mA output

  • AccuracyClass A
  • IP RatingIP65
  • Temp Range-40 to +150 C
  • SensorRTD PT1000
RIGEL 2 MT-RTD1K

PV module temperature sensor, PT1000 resistance output

  • AccuracyClass A
  • IP RatingIP65
  • Temp Range-40 to +150 C
  • SensorRTD PT1000
RIGEL 2 MT-RS485

PV module temperature sensor, RS485 Modbus RTU output

  • AccuracyClass A
  • IP RatingIP65
  • Temp Range-40 to +150 C
  • SensorRTD PT1000

Which Rigel 2 fits?

The three models measure the same way and differ in their output. Pick the input your logger has.

Compare all our weather sensors

What input does your data logger have?

Your match: RIGEL 2 MT-A420

RIGEL 2 MT-A420

Your match

RIGEL 2 MT-A420

PV module temperature sensor, analog 4-20 mA output

  • Output4 to 20 mA Current
  • Current consumption0.5 mA
  • Operating temperature-40 C to +150 C

This is the model on show

Show this model
RIGEL 2 MT-RTD1K

Your match

RIGEL 2 MT-RTD1K

PV module temperature sensor, PT1000 resistance output

  • OutputResistance Output (PT1000)
  • Resolution0.001 C
  • Operating temperature-40 C to +150 C

This is the model on show

Show this model
RIGEL 2 MT-RS485

Your match

RIGEL 2 MT-RS485

PV module temperature sensor, RS485 Modbus RTU output

  • OutputRS485 MODBUS RTU
  • Supply voltage12 VDC / 24 VDC
  • Operating temperature-40 C to +80 C

This is the model on show

Show this model

RIGEL 2 MT-A420

Rigel 2 MT-A420 is the analog version of Rigel 2, with a 4-20 mA current output for data loggers and SCADA analog inputs. It measures PV module back-surface temperature with an IEC 60751 Class A PT1000 element, for IEC 61724-1:2021 Class A monitoring systems.

Features

  • Class A Accuracy

    The PT1000 element meets the IEC 60751 Class A tolerance, ±(0.15 + 0.002|t|) °C, suitable for IEC 61724-1:2021 Class A monitoring systems.

  • Faster Thermal Response

    Ultra-low-mass RTD PT1000 element delivers sub-second thermal response — capturing rapid PV module temperature changes with fidelity.

  • Bifacial PV Ready

    Low-profile 7.2 mm body mounts flush on the rear surface of bifacial modules without obstructing rear-side irradiance.

  • IP65 Rugged Body

    Aluminium 6082 enclosure with IP65 ingress protection — sealed for deployment across desert, tropical, and coastal environments.

  • Self-Adhesive Mount

    Ships with a high-performance VHB adhesive pad rated for −40°C to +150°C — module-ready in minutes, no drilling or tools needed.

  • 3 Output Variants

    Available in Analog 4–20 mA (MT-A420), PT1000 Resistance (MT-RTD1K), and RS485 Modbus RTU (MT-RS485) — integrates with any data logger or SCADA system.

Technical Specifications

RIGEL 2 MT-A420

Specifications

Output Signal4 to 20 mA Current
Temperature Range-40 C to +150 C
AccuracyIEC 60751 Class A, ±(0.15 + 0.002|t|) °C
Uncertainty+-0.3 deg
Resolution0.01 C
Sensor Element TypeRTD PT1000 Class A
Current Consumption0.5 mA

Physical

Operating Temperature-40 C to +150 C
Ingress ProtectionIP65
MaterialAluminium 6082
DimensionsDia. 25.4 mm x Thickness 7.2 mm
Weight<15 g (excl. cable weight)
Cable Diameter0.216 cm (0.085 in.)
Cable Length2 meters

* |t| is the numerical value of the temperature in C, irrespective of sign.

RIGEL 2 MT-RTD1K

Rigel 2 MT-RTD1K is the resistance version of Rigel 2: the PT1000 element is read directly by the data logger's RTD input. It measures PV module back-surface temperature with an IEC 60751 Class A PT1000 element, for IEC 61724-1:2021 Class A monitoring systems.

Features

  • Class A Accuracy

    The PT1000 element meets the IEC 60751 Class A tolerance, ±(0.15 + 0.002|t|) °C, suitable for IEC 61724-1:2021 Class A monitoring systems.

  • Faster Thermal Response

    Ultra-low-mass RTD PT1000 element delivers sub-second thermal response — capturing rapid PV module temperature changes with fidelity.

  • Bifacial PV Ready

    Low-profile 7.2 mm body mounts flush on the rear surface of bifacial modules without obstructing rear-side irradiance.

  • IP65 Rugged Body

    Aluminium 6082 enclosure with IP65 ingress protection — sealed for deployment across desert, tropical, and coastal environments.

  • Self-Adhesive Mount

    Ships with a high-performance VHB adhesive pad rated for −40°C to +150°C — module-ready in minutes, no drilling or tools needed.

  • 3 Output Variants

    Available in Analog 4–20 mA (MT-A420), PT1000 Resistance (MT-RTD1K), and RS485 Modbus RTU (MT-RS485) — integrates with any data logger or SCADA system.

Technical Specifications

RIGEL 2 MT-RTD1K

Physical

Operating Temperature-40 C to +150 C
Ingress ProtectionIP65
MaterialAluminium 6082
DimensionsDia. 25.4 mm x Thickness 7.2 mm
Weight<15 g (excl. cable weight)
Cable Diameter0.216 cm (0.085 in.)
Cable Length2 meters

Specifications

Output SignalResistance Output (PT1000)
Temperature Range-40 C to +150 C
AccuracyIEC 60751 Class A, ±(0.15 + 0.002|t|) °C
Resolution0.001 C
Sensor Element TypeRTD PT1000 Class A

* |t| is the numerical value of the temperature in C, irrespective of sign.

RIGEL 2 MT-RS485

Rigel 2 MT-RS485 is the digital version of Rigel 2, reporting over RS485 Modbus RTU to a data logger or SCADA system. It measures PV module back-surface temperature with an IEC 60751 Class A PT1000 element, for IEC 61724-1:2021 Class A monitoring systems.

Features

  • Class A Accuracy

    The PT1000 element meets the IEC 60751 Class A tolerance, ±(0.15 + 0.002|t|) °C, suitable for IEC 61724-1:2021 Class A monitoring systems.

  • Faster Thermal Response

    Ultra-low-mass RTD PT1000 element delivers sub-second thermal response — capturing rapid PV module temperature changes with fidelity.

  • Bifacial PV Ready

    Low-profile 7.2 mm body mounts flush on the rear surface of bifacial modules without obstructing rear-side irradiance.

  • IP65 Rugged Body

    Aluminium 6082 enclosure with IP65 ingress protection — sealed for deployment across desert, tropical, and coastal environments.

  • Self-Adhesive Mount

    Ships with a high-performance VHB adhesive pad rated for −40°C to +150°C — module-ready in minutes, no drilling or tools needed.

  • 3 Output Variants

    Available in Analog 4–20 mA (MT-A420), PT1000 Resistance (MT-RTD1K), and RS485 Modbus RTU (MT-RS485) — integrates with any data logger or SCADA system.

Technical Specifications

RIGEL 2 MT-RS485

Physical

Operating Temperature-40 C to +80 C
Ingress ProtectionIP65
Material (Sensing Element)Aluminium 6082
Material (Circuitry)ABS
Dimensions (Sensing Element)Dia. 25.4 mm x Thickness 7.2 mm
Weight<20 g (excl. cable weight)
Cable TypeLi2YD11Y-24 AWG BRD
Cable InsulationExtruded Polyurethane

Specifications

Output SignalRS485 MODBUS RTU
Temperature Sensing Range-40 C to +150 C
AccuracyIEC 60751 Class A, ±(0.15 + 0.002|t|) °C
Uncertainty+-0.3 deg
Resolution0.01 C
Sensor Element TypeRTD PT1000 Class A
Supply Voltage12 VDC / 24 VDC

* |t| is the numerical value of the temperature in C, irrespective of sign.

Applications

  • Solar PV Module Temperature Monitoring

    The Rigel 2 is the IEC-specified sensor for back-of-module (BOM) temperature measurement on mono- and bifacial PV panels — essential for Performance Ratio and yield assessment.

  • Surface Temperature Monitoring

    Wide operating range from −40°C to +150°C and IP65 protection make the Rigel 2 suitable for general-purpose surface temperature measurement on outdoor structures and equipment.

Built to Work Together

The Altair ATRH sensor, Rigel 2 module sensor, and Xtreme data logger form one bankable monitoring chain — from field to cloud.

  1. 1

    Altair / Rigel

    Sensor. Measure air temperature, humidity and PV module temperature to IEC 61724-1:2021 Class A.

  2. 2

    Xtreme XG

    Logger. Reads every sensor on site, stores the data and sends it on over Ethernet, Wi-Fi or LTE.

  3. 3

    DaLI

    Firmware. The web console built into every Xtreme station, for setup and checks on site.

  4. 4

    Live3

    Cloud. See every station, get told when something is wrong, and fix it without a site visit.

Select Your Model

MT-A420Analog 4-20 mA, product code 55009
MT-RTD1KPT1000 Resistance, product code 55006
MT-RS485RS485 Modbus RTU, product code 55020
ComplianceIEC 61724-1:2021
AccuracyClass A

Contact

Ask for a price on Rigel 2, or talk to one of our engineers about your application.

Offices

India

Head office and design centre, Pune

Plot No. 7, Lane No. 5, Laxman Nagar, Balewadi
Pune, Maharashtra 411045, India

Open in Google Maps

Factory, Pune

Vivan Kohli Industrial Park, Shed No. 5, Gat No. 446
Old Pune-Mumbai Highway, Naigaon, Kanhe Phata, Talegaon
Pune, Maharashtra 412106, India

Open in Google Maps

Sales and support, Bengaluru

First Floor, Building No. 11, Sai Anugraha
Jeevan Bhima Nagar Main Road
Bengaluru, Karnataka 560075, India

Open in Google Maps

Sales and support, Vijayawada

Door No. 52-1/4-8D, Plot No. 9, 5th Cross Road
Veterinary Colony
Vijayawada, Andhra Pradesh 520008, India

Open in Google Maps

International

Aeron Systems Pvt. Ltd., Sharjah

Saif Executive Office # P8-17-02
Sharjah Airport International Free Zone Authority
PO Box 8000, Sharjah, U.A.E.

Open in Google Maps