Your match
RIGEL 2 MT-A420
PV module temperature sensor, analog 4-20 mA output
- Output4 to 20 mA Current
- Current consumption0.5 mA
- Operating temperature-40 C to +150 C
This is the model on show
Show this modelWeather Sensors

PV module temperature sensor, analog 4-20 mA output

PV module temperature sensor, PT1000 resistance output

PV module temperature sensor, RS485 Modbus RTU output
The three models measure the same way and differ in their output. Pick the input your logger has.
Compare all our weather sensorsWhat input does your data logger have?
Your match: RIGEL 2 MT-A420

Your match
PV module temperature sensor, analog 4-20 mA output
This is the model on show
Show this model
Your match
PV module temperature sensor, PT1000 resistance output
This is the model on show
Show this model
Your match
PV module temperature sensor, RS485 Modbus RTU output
This is the model on show
Show this modelRigel 2 MT-A420 is the analog version of Rigel 2, with a 4-20 mA current output for data loggers and SCADA analog inputs. It measures PV module back-surface temperature with an IEC 60751 Class A PT1000 element, for IEC 61724-1:2021 Class A monitoring systems.
The PT1000 element meets the IEC 60751 Class A tolerance, ±(0.15 + 0.002|t|) °C, suitable for IEC 61724-1:2021 Class A monitoring systems.
Ultra-low-mass RTD PT1000 element delivers sub-second thermal response — capturing rapid PV module temperature changes with fidelity.
Low-profile 7.2 mm body mounts flush on the rear surface of bifacial modules without obstructing rear-side irradiance.
Aluminium 6082 enclosure with IP65 ingress protection — sealed for deployment across desert, tropical, and coastal environments.
Ships with a high-performance VHB adhesive pad rated for −40°C to +150°C — module-ready in minutes, no drilling or tools needed.
Available in Analog 4–20 mA (MT-A420), PT1000 Resistance (MT-RTD1K), and RS485 Modbus RTU (MT-RS485) — integrates with any data logger or SCADA system.
| Output Signal | 4 to 20 mA Current |
|---|---|
| Temperature Range | -40 C to +150 C |
| Accuracy | IEC 60751 Class A, ±(0.15 + 0.002|t|) °C |
| Uncertainty | +-0.3 deg |
| Resolution | 0.01 C |
| Sensor Element Type | RTD PT1000 Class A |
| Current Consumption | 0.5 mA |
| Operating Temperature | -40 C to +150 C |
|---|---|
| Ingress Protection | IP65 |
| Material | Aluminium 6082 |
| Dimensions | Dia. 25.4 mm x Thickness 7.2 mm |
| Weight | <15 g (excl. cable weight) |
| Cable Diameter | 0.216 cm (0.085 in.) |
| Cable Length | 2 meters |
* |t| is the numerical value of the temperature in C, irrespective of sign.
Rigel 2 MT-RTD1K is the resistance version of Rigel 2: the PT1000 element is read directly by the data logger's RTD input. It measures PV module back-surface temperature with an IEC 60751 Class A PT1000 element, for IEC 61724-1:2021 Class A monitoring systems.
The PT1000 element meets the IEC 60751 Class A tolerance, ±(0.15 + 0.002|t|) °C, suitable for IEC 61724-1:2021 Class A monitoring systems.
Ultra-low-mass RTD PT1000 element delivers sub-second thermal response — capturing rapid PV module temperature changes with fidelity.
Low-profile 7.2 mm body mounts flush on the rear surface of bifacial modules without obstructing rear-side irradiance.
Aluminium 6082 enclosure with IP65 ingress protection — sealed for deployment across desert, tropical, and coastal environments.
Ships with a high-performance VHB adhesive pad rated for −40°C to +150°C — module-ready in minutes, no drilling or tools needed.
Available in Analog 4–20 mA (MT-A420), PT1000 Resistance (MT-RTD1K), and RS485 Modbus RTU (MT-RS485) — integrates with any data logger or SCADA system.
| Operating Temperature | -40 C to +150 C |
|---|---|
| Ingress Protection | IP65 |
| Material | Aluminium 6082 |
| Dimensions | Dia. 25.4 mm x Thickness 7.2 mm |
| Weight | <15 g (excl. cable weight) |
| Cable Diameter | 0.216 cm (0.085 in.) |
| Cable Length | 2 meters |
| Output Signal | Resistance Output (PT1000) |
|---|---|
| Temperature Range | -40 C to +150 C |
| Accuracy | IEC 60751 Class A, ±(0.15 + 0.002|t|) °C |
| Resolution | 0.001 C |
| Sensor Element Type | RTD PT1000 Class A |
* |t| is the numerical value of the temperature in C, irrespective of sign.
Rigel 2 MT-RS485 is the digital version of Rigel 2, reporting over RS485 Modbus RTU to a data logger or SCADA system. It measures PV module back-surface temperature with an IEC 60751 Class A PT1000 element, for IEC 61724-1:2021 Class A monitoring systems.
The PT1000 element meets the IEC 60751 Class A tolerance, ±(0.15 + 0.002|t|) °C, suitable for IEC 61724-1:2021 Class A monitoring systems.
Ultra-low-mass RTD PT1000 element delivers sub-second thermal response — capturing rapid PV module temperature changes with fidelity.
Low-profile 7.2 mm body mounts flush on the rear surface of bifacial modules without obstructing rear-side irradiance.
Aluminium 6082 enclosure with IP65 ingress protection — sealed for deployment across desert, tropical, and coastal environments.
Ships with a high-performance VHB adhesive pad rated for −40°C to +150°C — module-ready in minutes, no drilling or tools needed.
Available in Analog 4–20 mA (MT-A420), PT1000 Resistance (MT-RTD1K), and RS485 Modbus RTU (MT-RS485) — integrates with any data logger or SCADA system.
| Operating Temperature | -40 C to +80 C |
|---|---|
| Ingress Protection | IP65 |
| Material (Sensing Element) | Aluminium 6082 |
| Material (Circuitry) | ABS |
| Dimensions (Sensing Element) | Dia. 25.4 mm x Thickness 7.2 mm |
| Weight | <20 g (excl. cable weight) |
| Cable Type | Li2YD11Y-24 AWG BRD |
| Cable Insulation | Extruded Polyurethane |
| Output Signal | RS485 MODBUS RTU |
|---|---|
| Temperature Sensing Range | -40 C to +150 C |
| Accuracy | IEC 60751 Class A, ±(0.15 + 0.002|t|) °C |
| Uncertainty | +-0.3 deg |
| Resolution | 0.01 C |
| Sensor Element Type | RTD PT1000 Class A |
| Supply Voltage | 12 VDC / 24 VDC |
* |t| is the numerical value of the temperature in C, irrespective of sign.
The Rigel 2 is the IEC-specified sensor for back-of-module (BOM) temperature measurement on mono- and bifacial PV panels — essential for Performance Ratio and yield assessment.
Wide operating range from −40°C to +150°C and IP65 protection make the Rigel 2 suitable for general-purpose surface temperature measurement on outdoor structures and equipment.
The Altair ATRH sensor, Rigel 2 module sensor, and Xtreme data logger form one bankable monitoring chain — from field to cloud.
Sensor. Measure air temperature, humidity and PV module temperature to IEC 61724-1:2021 Class A.
Logger. Reads every sensor on site, stores the data and sends it on over Ethernet, Wi-Fi or LTE.
Firmware. The web console built into every Xtreme station, for setup and checks on site.
Cloud. See every station, get told when something is wrong, and fix it without a site visit.
| MT-A420 | Analog 4-20 mA, product code 55009 |
|---|---|
| MT-RTD1K | PT1000 Resistance, product code 55006 |
| MT-RS485 | RS485 Modbus RTU, product code 55020 |
| Compliance | IEC 61724-1:2021 |
| Accuracy | Class A |
Other products from Renewable & Weather Tech.
Ask for a price on Rigel 2, or talk to one of our engineers about your application.
Sales
Products, quotes and demos
Technical support
Help with an installed product
Careers
Jobs and applications
India
Plot No. 7, Lane No. 5, Laxman Nagar, Balewadi
Pune, Maharashtra 411045, India
Vivan Kohli Industrial Park, Shed No. 5, Gat No. 446
Old Pune-Mumbai Highway, Naigaon, Kanhe Phata, Talegaon
Pune, Maharashtra 412106, India
First Floor, Building No. 11, Sai Anugraha
Jeevan Bhima Nagar Main Road
Bengaluru, Karnataka 560075, India
Door No. 52-1/4-8D, Plot No. 9, 5th Cross Road
Veterinary Colony
Vijayawada, Andhra Pradesh 520008, India
International
Saif Executive Office # P8-17-02
Sharjah Airport International Free Zone Authority
PO Box 8000, Sharjah, U.A.E.